Autopilot APCETHD 매뉴얼 - 페이지 5

{카테고리_이름} Autopilot APCETHD에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Autopilot APCETHD 18 페이지.

Page 4
APCETHD
CO2 buttons
CO2 Mode - Press button to change the CO2 Mode. Selecting
will disable the CO2 output when the Cooling output is
dAYlocK
turned on (exhaust fans are running) Selecting
will
dAYFrEE
allow the CO2 and Cooling outputs to be on at the same time.
Use this mode if you are using air conditioning to cool.
CO2 ON time - Press this button to set the amount of time the
CO2 output will be turned ON for. CO2 will be released or
produced during this time.
CO2 OFF time - Press this button to set the amount of time the
CO2 output will be turned OFF for. The CO2 device will remain
turned OFF during this time.
Note: The CO2 timers can also be used as a standard
DAYTIME recycling timer if it is not used as a CO2
timer. (Select dAYFrEE mode)
Split Mode buttons
Temp/Humidity Lock - Press button to lock or split the humidity
and temperature functions. The user has the option to run both at
the same time or independently.
Min/Maximum Temp - Press this button to recall the stored high
and low recorded levels for Temperature. Press and hold the
Enter/Reset button while the recorded value is displayed to reset
the Min/Max values.
Min/Maximum Humid - Press this button to recall the stored high
and low recorded levels for Humidity. Press and hold the
Enter/Reset button while the recorded value is displayed to reset
the Min/Max values.
*To change the temperature reading from F to C, press
and hold the UP and DOWN buttons for 2-3 seconds.