Autopilot ECLIPSE F90 사용자 설명서 - 페이지 7
{카테고리_이름} Autopilot ECLIPSE F90에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Autopilot ECLIPSE F90 12 페이지. Master environmental controller

CO
PPM SETTINGS
2
CO
LEVELS: Click the CO2 PPM knob and turn to set the PPM target. Click again to confirm the
2
setting.
CO
DEADBAND: Click the DEADBAND knob and turn to set the desired deadband setting. Click
2
again to confirm the setting.
Example: For CO
start to work at or below 1000 and turn off at 1050 PPM. For CO
or above 1000 PPM and turn off at 950 PPM.
MIN/MAX RECALL: Click and hold the CO
the CO
min/max PPM record. The display will show L XXX, H XXX. The screen will return to normal
2
display after 5 seconds (or immediately if you click both knobs simultaneously again), and the
record will be reset.
CALIBRATION: Place the CO
CAL/400, if you need to change the calibration level, turn the left knob. Keep the sensor from direct
sunlight and any breathing. Allow it 10 minutes to stabilize the PPM reading. The Screen will return
to normal display once the calibration is complete.
CO
& TEMP LOCK/UNLOCK SWITCH
2
LOCK: This setting will not allow the CO
will always be deactivated when the Cooling outlet is activated On. Lock setting is recommended
for rooms applying CO
minimizes CO
loss when the exhaust fan is operating.
2
UNLOCK: The CO
enrichment device and any cooling device that is plugged in are independently
2
controlled.
TEMPERATURE SETTINGS
The unit offers both day and night temperature control. Select either the heating or cooling mode
option.
DAY TEMP SETTING: There is a Day Cooling set point and a Day Heating set point.
1. To set the Day Cooling, Click the DAY TEMP knob. "COOL" will be displayed. To change the
setting, turn the DAY TEMP knob to select your desired temperature. Click again to accept the
new setting.
2. "HEAT" will then be displayed. Turn the DAY TEMP knob to select your desired setting, then click
the knob again to save the new setting.
NIGHT TEMP SETTING: Night temps are set exactly the same way as described above for day
temps, but using the NIGHT TEMP knob this time.
TEMP MIN/MAX RECALL: Press the DAY TEMP and NIGHT TEMP knobs simultaneously to recall the
min/max temperature record.
TEMP UNIT: Press and hold the DAY TEMP and NIGHT TEMP knobs simultaneously knobs for 3
seconds, then turn the DAY TEMP knob to select the desired temperature unit (°F or °C). Press both
simultaneously again to confirm the setting.
HUMIDITY & TEMPERATURE (RH% & TEMP) LOCK/UNLOCK SWITCH
LOCK: This setting locks both the temperature and humidity outlets together making them operate
simultaneously. Example: if the sensor detects a reading outside of the programmed Temperature
setting the unit will activate both Temperature and Humidity outlets at the same time. Use this
OPERATING INSTRUCTIONS
increase mode, if setpoint=1000 PPM and deadband=50 PPM, the CO
2
sensor outdoors, press both knobs for 3 seconds, display screen reads
2
2
that are also operating an exhaust fan for temperature control. This setting
2
PPM and DEADBAND knobs simultaneously to display
2
and Temp outlets to run simultaneously. The CO
7
decrease mode, the fan will start at
2
output will
2
outlet
2