DCI LLC PoE PSE TP-Fiber 사용자 설명서 - 페이지 13
{카테고리_이름} DCI LLC PoE PSE TP-Fiber에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DCI LLC PoE PSE TP-Fiber 15 페이지. 10/100base-tx to 100base-fx poe pse fe media converter;
8. Connecting to TP, Fiber Device
Converter
TP Port
10/100TP
Converter
Fiber Port
100FX
RESET
Fig. 12 Reset button and S1—Bit 1, 2, 3, 4, 5, 6
Reset
S1-1 TP port mode
S1-2 TP port speed
S1-3 TP port duplex : FDX or HDX when TP at Force
S1-4 LFP
S1-5 Fiber port duplex: 100FDX(default) or 100HDX
S1-6 PoE ON/OFF
Note:
1. S1-2 and S1-3 will take effect only when S1-1 is set at TP-FORCE.
2. S1-5 must be set to 100FDX for Single Fiber Model.
3. S1-6 must be set to PoE ON while power supplies to PD.
Warning:
—When TP Nway port is connected to TP 100FDX(force mode) instead of Nway
partner, it will result in 100HDX mode with invalid collision signal
—Ensure that all network nodes are configured at an identical operation mode.
Improper operation and flow control mode between TP and Fiber port connections
will render the LAN to work poorly.
AUTO, FORCE selectable: Bit 1, 2, 3 of S1
a. AUTO: 10/100 NWay Auto-negotiation
b. FORCE: 100 or 10, FDX or HDX
100Mbps duplex selectable: Bit 5 of S1
a. FDX for 100FDX fiber link partner, default
b. HDX for 100HDX fiber link partner
TP-AUTO 100
S1
1
2
TP-FORCE 10
HDX
Configuration and Setting
: Once S1-1, S1-2, S1-3, S1-4 or S1-5 is changed, please press
this button to have the setting taken effect.
: AUTO(default) or FORCE
: 100 or 10 when TP at Force
: LFP enabled(default) or disabled
: Enable(default) or disable
LFP
FDX EN FDX-FX PoE
3
4
5
6
LFP HDX-FX PoE
DIS
DIS
8