Dynasty Spas SC-MP-DY4 빠른 참조 카드 - 페이지 2
{카테고리_이름} Dynasty Spas SC-MP-DY4에 대한 빠른 참조 카드을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynasty Spas SC-MP-DY4 2 페이지. Excalibur series
Automaticwaterheaterstart:
When water temperature is 1˚F (0.5˚C) lower than
the Set Point, the heater will automatically turn on until
water temperature reaches Set Point plus 1˚F (0.5˚C).
The "Heater" indicator lights up when the heater is
on. It flashes when there is a request for more
heat but the heater has not yet started.
N.B.: If your system is configured in Low Current Mode,
the heater will not start if a pump is on at high speed.
PROGRAMMINGFILTERCYCLEDURATION
The system automatically performs two filter cycles per day, at 12-hour intervals.
During a filter cycle: Pump 2 runs for one minute, then Pump 1 runs at low speed for the programmed number of hours
The "Filter Cycle" indicator lights up when the filter cycle is on. To set filter cycle duration:
Press and hold Filter key
until the display shows "xx",
representing the currently
set filter cycle duration in
hours.
The filter cycle is suspended if the water temperature
raises more than 2˚F (1˚C) above Set Point or if spa
is in use (pumps started manually). The "Filter" icon
will blink (on 0.5 second, off 0.5 second, on 0.5
second, off 1.5 seconds).
TROUBLESHOOTING
Use Up or Down arrow keys
to change setting.
0 = no filtration
12 = continuous filtration
Pumps have started up for one
minute on several occasions and
"Filter Cycle" indicator is flashing.
3 flashing dots are displayed.
Water temperature is flashing.
The display is flashing.
Economymode:
Press Econo key to switch from Normal mode
to Economy mode. In Economy mode, system
maintains temperature at the desired Set Point
during filter cycles only. Set Point is 20˚F (11˚C)
below the Normal mode Set Point for the rest
of the time. In Economy mode, the display will
toggle between the current water temperature
and the "Econ" message.
N.B.: After a power failure, the filter cycle duration
will return to its default value (2 hours). In this case,
the first filter cycle will start one minute after power
has been restored.
Not a bug but a feature!
Our Smart Winter Mode protects your spa from the
cold by automatically turning pumps on for one minute
several times a day to prevent water from freezing in pipes.
A problem has been detected.
Do not enter the water! Check and open water valves.
Clean filter if necessary. Check water level. Add water
if needed.
Shut power off and power your spa up again to reset the
system.
Call your dealer or service supplier if problem persists.
Water temperature in the spa has reached 112˚F (44˚C).
Do not enter the water! Allow water to cool down. The
system will reset automatically when water temperature
reaches 109˚F (43˚C).
Call your dealer or service supplier if problem persists.
A power failure has occurred.
Press any key to reset the system, then reprogram all
desired parameters.
When the desired setting is dis-
played, press Filter key to confirm.
A filter cycle starts immediately.
Note: Light needs to be turned
off before the filter cycle can be
programmed.
9919-100496-C
Smart
Winter
Mode
TM