Highland heat Kompakt 20 사용자 설명서 - 페이지 15
{카테고리_이름} Highland heat Kompakt 20에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Highland heat Kompakt 20 20 페이지. Solid fuel boiler
Kompakt
5. Using the boiler
5.4 Boiler operation
1) Depending on the heat demand and burning intensity,
refuel periodically.
2) When leaving the boiler to operate during the night, the air
supply valve can be set - thereby reducing the boiler power. But
after reducing the air supply too much, it starts to accumulate
soot on the walls of the boiler and the efficiency of the boiler
decreases.
3) The boiler door must be closed during operation.
5.5 Maintenance
Ashtray.
Clean the ashtray as needed, depending on the type of fuel
used. A full ashtray prevents the proper combustion of fuel -
improper air distribution occurs, so the fuel burns unevenly
along the entire length of the boiler.
Cleaning.
It is recommended that all combustion waste and slag be
cleaned before each new ignition. The heat exchanger is easily
cleaned through the upper door. The combustion chamber is
cleaned through the middle door. Cleaning of cast iron grates
and ashtray is done by pulling out the components through the
bottom door.
Recommendations.
• The tar layer formed inside the boiler can be reduced by
burning aspen or black alder wood at maximum temperature.
• Periodically inspect the boiler and heating system.
15