INSTALLATION INSTRUCTIONS
GAS CONNECTHON FOR CT-365
GAS CONNECTHON FOR CT-304
COUNTER TOP
COUNTER TOP
Required
when
unit
is h_stal]ed
over
Wall
Oven
Power
Requirements:
120 VAC, 60 Hz., singHe phase.
CT-304/CT-365:0.10
Amp. Max.
(Use 15 Amp.circuit
minimum)
I
AHways disconnect
the eHectric suppHy cord from the wall] outlier or turn off:he
eHectricity at the
service disconnect
before servicing
this appHhnce.
I
Observe all]governing
codes and ordinances
when grounding,
in the absence of which,observe
Nationa] EHectrica] Code ANSI/NFPA No. 70-1990.
Recommended
Grounding
Method:
This appliance
is factory equipped
with a power supply cord with a three-prong
grounding
plug (with
polarized
parallel blades). It must be plugged
into a mating grounding-type
receptacle, connected
to
a correctly
polarized
120 Volt circuit. If the circuit does not have a grounding
type receptacle, it is the
responsibility
and obligation
of the installer
or user to have the existing
receptacle
changed
to a
properly
grounded
and
polarized
receptacle
in accordance
with
all applicable
local codes
and
ordinances
by a qualified
electrician.
In the absence of local codes and ordinances,
the receptacle
replacement
shall be in accordance
with the National
Electrical Code. THE THIRD GROUND
PRONG
SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED.The
electrical
supply must be a
120 volt, 60 Hz single phase, 15 AMP circuit.The
power receptacle
must be a NEMA 5q5R device to
accept the three prong plug supplied with the unit.
_THIRD GROUND PRONG
10