If your network does not have a PoE enabled network switch, you will need to use a power
injector with the clock. A power injector passes Ethernet communications through while also
injecting power in accordance with the IEEE 802.3af standard.
The above diagram shows how a power injector fits into the set up. If you have a power injector
supplied by Galleon, connect the hub/switch to the port labelled "LAN" on the power injector and
connect the clock to the port labelled "PoE" on the power injector. Plug the power supply in and
wait for the clock's display to come on. When the unit powers up, make a note of the IP address,
as this will be needed to configure the unit via the web interface.

2. DHCP SERVER

By default, the SignalClock is set to use DHCP to obtain its IP Address. If the clock is unable to
receive network settings from the DHCP server, the clock will cycle: '----'. If the clock is unable to
obtain an IP address after several attempts, it will set its IP address to 169.254.0.1. This is done so
that the unit can be configured without requiring a DHCP server.
Once the unit has obtained an IP address from a DHCP server on your network, configuration (such
as static network settings) can be applied to the clock. For help with this, please see the "Web
Configuration" section of this manual.