DCS DCS-VH-36HS 사용 및 설치 매뉴얼 - 페이지 11

{카테고리_이름} DCS DCS-VH-36HS에 대한 사용 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DCS DCS-VH-36HS 18 페이지. The professional vent hoods
DCS DCS-VH-36HS에 대해서도 마찬가지입니다: 사용 및 설치 매뉴얼 (18 페이지)

DCS DCS-VH-36HS 사용 및 설치 매뉴얼
GENERAL:
When planning the path for ducting to the outside, keep in
mind the following guidelines:
Minimize use of elbows and transitions in ductwork
as to
maximize air flow to outside of building. An efficient airflow
path contributes
to the overall efficiency of theVent Hood.
DCS recommends the use of smooth wall ducting, not
flexible ductwork.
Transitions are required from rectangular to round ducting
Vertical
Duct
Transition
DCS-IBI2
BLOWER Requires one of the following 4-1/2" x 18" to 10" round transitions
(purchase separately)
Model 19052-0 I-Vertical
discharge
Model 19052-02-Rear discharge
Model 19052-03-Left discharge
Duct tape may be used at ducting joints.
DCS-VH-48
/ DCS-VH
12-36 REQUIREMENTS:
DCS recommends the use of 10" round ducting which provides 78.6 sq. In. of surface area.
Alternate
duct sizes in rectangular style may be used. If a rectangular duct style is used, the duct
must equal at least 78.6 sq. In. for best results. (Example- 3-1/4" x 24" duct = 78 sq. In.)
Maintain consistent ducting square area as to avoid reduced air flow.
[ie.-With
aVH-48
Hood,
connecting a 4"xl3"
(52 sq. In.) to a 10" round (78.6 sq. In.) is not recommended]
DCS-VH-36/30
REQUIREMENTS:
DCS recommends the use of 7" round ducting which provides 34.7 sq. In. of surface area.
Alternate
duct sizes in rectangular style may be used. If a rectangular duct style is used, the duct
must equal at least 34.7 sq. In. for best results.
DUCT ACCESSORIES:
Wall Caps and Roof Caps must have free open area equal to duct size diameter.
Note that a Sealed Back Draft Damper may reduce air delivery.
10