SSD7105&7202&7502&7505&7540&7580A&7580B Boot RAID Windows Installation Guide
Enter the command to check that the quick shutdown is turned off;
powercfg / a

Trouble shooting

No supporting host adapter is found

In the UEFI environment, run the command, " go.nsh (Please see UEFI Read me for specific
.
input content.)"
Solutions: If you get the message, "No supporting host adapter is found. "Try the following,
a. The error message is to remind the user that when the card cannot be found in UEFI. Make
sure the SSD7000/SSD7500 Series NVMe Controller is installed into a PCIe slot with x8 or
x16 lane.
b. In order to avoid this slot is broken, so replace the slot and test again.

No supported controller detected

In the UEFI environment, run the command, "ArrayCreate.efi".
Solutions: If you get the message, "No supported controller detected." Try the following,
a.
Check whether the Storage option ROM is Enabled in the motherboard BIOS.