Section 363-703-103
Revision 01
A. PRODUCT OVERVIEW

1. DESCRIPTION AND FEATURES

1.01
The PG-Flex FLC-703 Channel Unit provides 8
POTS interfaces between the Central Office and
PG-Flex, and uses µ-Law PCM encoding. The Model FLC-
703 Channel Unit includes green status LEDs for each line
indicating idle, ringing, and off-hook conditions, as well as a
red LED indicating a fault condition on the Channel Unit.
The unit provides metallic test access to the subscriber line
connection through an optional metallic bypass pair.
1.02
Revision History of this practice.
Revision 02—December 18, 1996
a) Added List 3.
1.03
Features of the PG-Flex FLC-703 COT Channel
Unit:
• Eight POTS subscriber interfaces
• 64 kbps µ-Law PCM encoding
• Front panel ACTIVE LEDs indicate idle, ringing,
test access, and off-hook for each channel
• Front panel FAULT LED indicator simplifies
troubleshooting
• Pair Gain Test Controller (PGTC) Compatibility -
List 3 only
Page 2

2. APPLICATIONS

2.01
Subscriber Drop Testing. For subscriber drop
testing from the central office, PG-Flex is able to
select and connect any subscriber drop to a metallic test pair
at the RT. PG-Flex extends this connection back to the COT
where it can be switched onto the test access bus, or to the
corresponding subscriber line on the COT channel card.
2.02
Test access may be achieved by placing +116 V on
the subscriber's COT tip lead for 1.5 seconds, then
removing the +116 V. Depending on the configuration of the
PG-Flex system, the selected subscriber drop (assuming a
working metallic bypass pair) will be connected to either the
corresponding COT subscriber line or to the test access bus.
2.03
The test connection will be dropped when -116V is
applied to the subscriber's COT tip for 1.5 seconds,
then removing the -116 V.
2.04
Test access may also be activated through the
RS-232 Maintenance Port located on the front of the
COT Line Unit, using an ASCII terminal.