CopperOptics PairGain HiGain-2 HRU-612 매뉴얼 - 페이지 13

{카테고리_이름} CopperOptics PairGain HiGain-2 HRU-612에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CopperOptics PairGain HiGain-2 HRU-612 19 페이지. Remote unit

TABLE 3. HLU 4 CHARACTER FRONT PANEL MESSAGES (CONTINUED)
Message
VER
HLU Software Version #
LIST 0xL
HLU's List #
FRM
Frame:SF,ESF,UNFR,NONE
CODE
Line Code: AMI, B8ZS
LOSW
Loss of Sync Word
LLOS
Local Loss of Signal
RLOS
Remote Loss of Signal
DS1
DS1 BPV errors
DS0
DS0 Blocked Channels
Full Name
This is displayed during the System Settings review mode.
Depress the Mode button for 3 seconds.
Displayed during System Settings review mode defined
above.
Defines the type of frame pattern being received from the
DSX-1. Displayed during System Settings mode defined
above.
This is the line code that the HLU is set to receive and
transmit at its DSX-1 interface. Displayed during System
Settings mode defined above.
Indicates that the VHDSL loop has lost sync. Causes a
minor alarm.
Indicates that no signal is detected at the T1 input to the
HLU. Causes a minor alarm.
Indicates that no signal is detected at the T1 input to the
HRU. Causes a minor alarm.
Indicates that the number of BPVs at the HLU and HRU
DS1 inputs that have exceeded the 24 hour ES threshold.
Causes a minor alarm
Indicates status of DS0 blocked channels. NONE indicates
no channels are blocked. BLK indicates some channels are
blocked.
Section 150-612-100
Description
Revision 02
Page 13