OPERATIOn
Running an EDID Capture
before using the Isolator, run a one-time EDID capture. This prevents the
continuous transfer of potentially malicious data - from the display to
the PC – that could infect the PC, cause data leakage, and so on.
Preparation:
• Connect the PC and all peripherals to the unit, according to the
diagram.
• Make sure the PC, display, and unit are On.
EDID Lock
HSL Secure KVM Isolators Quick Setup Guide
1
2
To run an EDID capture:
1. On the PC SIDE, short-click the EDID LOCK button – for less than
one second. Warning: Long-clicking the EDID LOCK button sends
the unit into an undesired loop. If this happens, restart the unit and
repeat the procedure.At first, the EDID LED flickers for a few seconds
and then lights continuously.
Note: If the EDID LED is Off, check the connections and that the
display is powered On. Then, repeat the procedure.
2. Restart the unit.
Note: An EDID capture needs to be performed for new installations
and when changing a display.