Emerson Network Power NetSure 701 A41-S3 사용자 설명서 - 페이지 11
{카테고리_이름} Emerson Network Power NetSure 701 A41-S3에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Emerson Network Power NetSure 701 A41-S3 20 페이지. Subrack power system
Item
NetSure 501 A41-S1
Model:
Contorller
M221S/M222S
Model:
R48-1800A/R48-2000/
R48-2000e
Standard
Rectifier
configuration:4 pieces
AC power
L+N+PE/ 220Vac
distribution
BLVD load route:
2 × 16A/1P,
MCB
LLVD load route:
DC power
2 × 63A/1P,
distribution
2 × 32A/1P
MCB
Battery MCB
2 × 63A/1P
AC SPD
1 piece
DC SPD
1 piece
Max.size (mm)
483 × 360 × 222
BLVD contorller
Contorller power-off
mode
Weight
≤ 25kg
Notes:
1. Temperature sensor and connected cables, remote monitoring unit, battery rack.
2. The way of outage for control is cutting off the battery, disconnecting the monitor and storage battery, monitor dropping out and communication broken up.
Table 1-1 Configuration of fixed- configuration system
NetSure 501 A41-S2
NetSure 501 A91-S1 NetSure 701 A41-S1 NetSure 701 A41-S2 NetSure 701 A41-S3 NetSure 701 A41-S4 NetSure 701 A41-S5
Model:
Model:
M820B
M221S/M222S
Model:
Model:
R48-1800A/R48-2000/
R48-1800A/R48-2000
R48-2000e
/R48-2000e
Standard
Standard
configuration:4 pieces
configuration:5
pieces
L+N+PE/220Vac
3P+N+PE/380Vac
BLVD load route:
BLVD load route:
2 × 10A/1P,
5 × 63A/1P,
2 × 32A/1PMCB
5 × 32A/1P,
LLVD load route:
8 × 10A/1P
MCB
2 × 63A/1P,
LLVD load route:
2 × 32A/1P
MCB
Not configured
2 × 125A/1P
2 × 125A/1P
Optional
Optional
Optional
Optional
483 × 360 × 222
483 × 360 × 400
Contorller power-on
Contorller power-on
≤ 25kg
≤ 25kg
NetSure 701 A41, NetSure 501 A41, NetSure 501 A91 Subrack Power system User Manual
Model:
Model:
M221S/M222S
M221S/M222S
Model:
Model:
R48-2900U/R48-300
R48-2900U/
0e/R48-3200/R48-35
R48-3000e
00e/R48-4000e
R48- 3200
Standard
R48-3500e
configuration:3
R48-4000e
Standard
pieces
configuration:4
pieces
3P+N+PE/380Vac
L+N+PE/380Vac
BLVD load route:
BLVD load route:
1 × 10A/1P
4 × 63A/1P,
MCB
6 × 32A/1P,
LLVD load route:
2 × 10A/1P
MCB
4 × 40A/1P
LLVD load route:
MCB
Not configured
2 × 125A/1P
2 × 125A/1P
Optional
Optional
Optional
Optional
483 × 360 × 267
483 × 360 × 267
Contorller power-on
Contorller power-on
≤ 25kg
≤ 25kg
Chapter 1 Overview
Model:
Model:
M221S/M222S
M820B
Model:
Model:
R48-2900U/
R48-2900U/
R48-3000e
R48-3000e
R48- 3200
R48- 3200
R48-3500e
R48-3500e
R48-4000e
R48-4000e
Standard
Standard
configuration:4
configuration:4
pieces
pieces
3P+N+PE/ 220Vac 3P+N+PE/ 380Vac L+N+PE/ 220Vac
BLVD load route:
BLVD load route:
2 × 32A/1P,
2 × 63A/1P
2 × 16A/1P
4 × 32A/1P,
MCB
4 × 10A/1P
LLVD load route:
MCB
LLVD load route:
2×63A/1P,
2×100A/1P
4×32A/1P,
2×63A/1P,
2×16A/1P MCB
2×32A/1P MCB
2 × 125A/1P
2 × 125A/1P
1 piece
Optional
1 piece
Optional
483 × 360 × 267
483 × 360 × 400
Contorller power-off
Contorller power-on
≤ 25kg
≤ 25kg
3
Model:
M221S/M222S
Model:
R48-2900U/
R48-3000e
R48- 3200
R48-3500e
R48-4000e
Standard
configuration:4 个
BLVD load route:
2 × 32A/1P,
2 × 16A/1P
MCB
LLVD load route:
2×63A/1P, 4×
32A/1P MCB
2 × 125A/1P
1 piece
1 piece
483 × 360 × 267
Contorller power-off
≤ 25kg