Galvanic Isolator Gi-120/A 사용 설명서 - 페이지 7
{카테고리_이름} Galvanic Isolator Gi-120/A에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvanic Isolator Gi-120/A 7 페이지.
Model Gi-120/BK only
ONE (either) LED glowing
Disconnect
Start Battery
BOTH LEDs glowing
This indicates a possibility of AC (mains voltage) leakage. Proceed with great care
Danger of electrical shock. If in doubt, please consult a qualified electrician.
Unplug every appli-
ance connected to a
socket in turn, until
LED's are extinguished.
Resolved?
N
Disconnect
Leisure Batteries
Resolved?
N
Further testing
is beyond the scope
of this guide
Resolved?
N
Disconnect each AC
circuit in turn (using
circuit breakers where
fitted) until LED's are
extinguished.
Resolved?
N
Further testing
is beyond the scope
of this guide
Check Alternator, Bilge Wiring, Battery Casings.
Y
Reconnect battery, then disconnect all connected
circuits one at a time until resolved.
Check Alternator, Bilge Wiring, Battery Casings.
Y
Then disconnect all connected circuits one at a time
until resolved.
The last item you unplugged was a likely
Y
Cause of the fault. Rectify & re connect
Y
The last circuit disconnected was a
likely cause of the fault.
Rectify & re connect