Galvin Engineering 49820 설치 매뉴얼 - 페이지 3

{카테고리_이름} Galvin Engineering 49820에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvin Engineering 49820 4 페이지. Washing machine taps

Product Installation Guidelines
3. Testing
Once temperature indicator is fitted, check the operation of the unit and inspect for any leaks.
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
Handle is loose
SERVICE AND MAINTENANCE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the
jumper valve for wear and damage.
Replace if required.
6. Clean the spindle and body of debris.
7. Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product to re-
assembly method.
© Galvin Engineering Pty Ltd
CAUSE
Jumper valves are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Version 1, 7 October 2022, Page 3 of 4
RECTIFICATION
Replace jumper valve
Refurbish tap seat using a
reseating tool.
Replace o-ring
Turn water on
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Tighten locking ring