Galvin Engineering CliniLever TCWMC80CC 설치 매뉴얼 - 페이지 2

{카테고리_이름} Galvin Engineering CliniLever TCWMC80CC에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvin Engineering CliniLever TCWMC80CC 4 페이지. Cp-bs hospital washing machine tap

Galvin Engineering CliniLever TCWMC80CC 설치 매뉴얼
Product Installation Guidelines
PRE-INSTALLATION -
Wall Spud
− Wall spuds must be ½" BSP MI and protrude from the finished wall by no more than 15mm
Note: In some situations a male thread connection on the tap may be more suited. If so, please
contact Galvin Engineering.
½" BSP MI
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water
and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of
the product.
1. Fit washing machine body
Fit the washing machine body assembly with
the wall flange to the spud and fasten with a
spanner.
We recommend using thread tape or
equivalent to ensure the connection does not
leak.
DO NOT tighten the body by using the top
assembly.
© Galvin Engineering Pty Ltd
MOUNTING DETAILS
2. Fit handle
Ensure the spindle is in the closed position
and firmly press the lever handle onto the
spindle in the desired orientation.
Check lever handles for correct operation.
Secure the handle in position using the
supplied washer and stainless steel cap
screw.
Document No.: 001.00.10.17
Version 1, 4 November 2022, Page 2 of 4