Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01 설치 매뉴얼 - 페이지 2
{카테고리_이름} Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01 4 페이지. Remote push button drinking tap
v
PRE-INSTALLATION -
If the mounting holes do not already exist, mark out and drill
the holes in the bench/trough, as shown in rough-in
dimensions.
Note: Supplied flexi hose length is 225mm long.
Maximum distance between outlet and push button is 180mm.
Note: Before installation, all lines must be flushed.
We recommend that a line strainer be installed prior to drinking
taps to eliminate any foreign material.
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical
supply conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
1. Disassemble Handle and Mouthguard Outlet
Remove the push button and dress flange from
the inlet body.
Do not remove the whole top assembly
Remove back nut and cup washer from the
mouthguard outlet assembly
MOUNTING DETAILS
INLET BODY
INLET BODY
ROUGH-IN DIMENSIONS
ROUGH-IN DIMENSIONS
2. Fit Inlet Body & Mouthguard Outlet
Ensure the sealing rubber washers are placed
underneath the inlet body and mouthguard outlet.
Fit the inlet body and mouthguard outlet into the trough.
Fit washer, flange & locknut onto inlet body and hand
tighten.
27.0
th
Version 1, 12
March 2020 Page 2 of 4
180 MAX
190 MAX
33
28
MOUTHGUARD
OUTLET
OUTLET