Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01 설치 매뉴얼 - 페이지 2

{카테고리_이름} Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01 4 페이지. Remote push button drinking tap

Galvin Engineering Ezy-Drink Lead Safe 170.81.13.01 설치 매뉴얼
v
PRE-INSTALLATION -
If the mounting holes do not already exist, mark out and drill
the holes in the bench/trough, as shown in rough-in
dimensions.
Note: Supplied flexi hose length is 225mm long.
Maximum distance between outlet and push button is 180mm.
Note: Before installation, all lines must be flushed.
We recommend that a line strainer be installed prior to drinking
taps to eliminate any foreign material.
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical
supply conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
1. Disassemble Handle and Mouthguard Outlet
 Remove the push button and dress flange from
the inlet body.
 Do not remove the whole top assembly
Remove back nut and cup washer from the
mouthguard outlet assembly
MOUNTING DETAILS
INLET BODY
INLET BODY
ROUGH-IN DIMENSIONS
ROUGH-IN DIMENSIONS
2. Fit Inlet Body & Mouthguard Outlet
Ensure the sealing rubber washers are placed
underneath the inlet body and mouthguard outlet.
Fit the inlet body and mouthguard outlet into the trough.
Fit washer, flange & locknut onto inlet body and hand
tighten.
27.0
th
Version 1, 12
March 2020 Page 2 of 4
180 MAX
190 MAX
33
28
MOUTHGUARD
OUTLET
OUTLET