Hikari H93S 사용 설명서 - 페이지 10
{카테고리_이름} Hikari H93S에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Hikari H93S 20 페이지. Electrical control box
Output duty cycle of
P-16
soft down
Output duty cycle of
P-17
trimmer and thread
tension
The stitch pattern
began after the
P-18
termination of the
stitch, mode
selection
Solid after before
P-19
sewing stop
Attachment
button
P-20
select function mode
P-21
soft start speed 1
P-22
soft start speed 2
P-23
soft start speed 3
Presser foot soft
P-24
lowering
function
Presser foot lift
P-25
function
Function of over
P-26
thickness
Power on and
P-27
positioning
Signal mode for
P-28
turn/lift switch
Presser foot soft
P-29
lowering time
Baseline count
P-30
enable
Baseline initial value
P-31
setting
Standard joint speed
P-34
mode selection
Multiple ratio of
P-35
counting by piece
number of stitches is the number of stitches × set
the value
output duty cycle of soft down
Output duty cycle of trimmer and thread tension
(too small will affect trimmer and tension solenoid
suction power)
The stitch without pattern began after the
termination of the stitch mode
selection 0: unavailable 1: available
0: unavailable 1: available
0 : unavailable
1 : Manual thread trimming in
standby 2:Manual adjust presser foot after thread
trimming
speed of the 1st needle of soft start
speed of the 2nd needle of soft start
speed of the 3 rd~9th needle of soft start
Setting to protect damaged the fabric to slow down
the presser foot lowering speed
Presser foot lift function set
0: unavailable 1: available 2:available after
trimming
Setting the function of over thickness
0:unavailable 1: available
The function setting of automatically finding the
needle position when the power is on 0:
unavailable 1: available
Setting of signal mode of turn/lift switch of
machine head 0: always open 1: always close
2:forbid a protection
To set presser foot soft lowering time The longer
time the lower speed of the presser foot
0: unavailable 1: Auto count when cycle to the set
value 2:Auto stop when count to set value
Baseline initial value setting
Select 0 automatic for standard joint speed mode;
1 pedal control
Setting of multiple ratio of counting by piece
7
0~100
8
0~100
50
0/1
0
0/1
0
0/1/2
0
100~3000(rp
400
m)
100~3000(rp
1000
m)
100~3000(rp
1500
m)
0/1
1
0/1/2
1
0/1
0
0/1
0
0/1/2
0
10~500(ms)
150
0/1/2
0
200~4000(0.
1600
1m)
0/1
0
0~50
0
2
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
1