{카테고리_이름} AIREDALE AIR 1-550.30에 대한 설치 및 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AIREDALE AIR 1-550.30 16 페이지. Steam/hot water unit heaters

HOT WATER PERFORMANCE DATA - LOW OUTLET TEMPERATURE MODELS
Table 11.1 - Performance Data for Low Outlet Temperature Units at Standard Conditions of
200°F Entering Water and 60°F Entering Air – High Motor Speed
Type
Model No.
WTC/WSC 18L
WTC/WSC 24L
WTC/WSC 33L
WTC/WSC 47L
WTC/WSC 63L
WTC/WSC 86L
Horizontal
Delivery
WTC/WSC 108L
WTC/WSC 121L
WTC/WSC 165L
WTC/WSC 258L
WTC/WSC 290L
WTC/WSC 340L
Power-
Throw™
WPC/WPN 610L 344,900
ƒ
WVC 42L
WVC 59L
WVC 78L
WVC 95L
WVC/WVN 139L
WVC/WVN 161L
WVC/WVN 193L
Vertical
Delivery
WVC/WVN 212L 123,400
ƒ
WVC/WVN 247L 143,600
WVC/WVN 279L 162,200
WVC/WVN 333L 198,300
WVC/WVN 385L 229,100
WVC/WVN 500L 295,000
WVC/WVN 610L 344,900
WVC 952L
Table 11.2 - Performance Data for Low Outlet Temperature Units at Standard Conditions of
200°F Entering Water and 60°F Entering Air – Reduced Motor Speeds
Type
Model No.
WTC/WSC 18L
WTC/WSC 24L
WTC/WSC 33L
Horizontal
WTC/WSC 47L
Delivery
WTC/WSC 63L
WTC/WSC 86L
WTC/WSC 108L
j Horizontal units with horizontal louvers open 30° from vertical plane. Vertical types equipped with cone jet deflector, blades fully opened are shown in bold.
Non-bolded mounting height/spread data is for units without deflectors.
k CFM for horizontal types is entering CFM. CFM for vertical and "Power-Throw" types is leaving CFM.
➂ WVC and WPC models have copper tubes, WVN and WPN models have 90/10 cupro-nickel tubes.
➃ Requires Solid State Motor Speed Controller.
Water Data
Pressure
Btu/hr
Drop
GPM
(Ft. of
Water)
11,300
1.2
0.4
13,700
1.4
0.6
19,300
2.0
0.2
21,100
2.2
0.2
37,900
4.0
0.4
44,600
4.6
0.6
66,100
6.9
1.8
66,700
6.9
1.9
113,200
11.8
6.6
147,400
15.4
3.2
161,100
16.8
3.7
200,900
20.9
6.6
35.9
0.6
6.0 / 100.0
23,000
2.4
0.4
32,600
3.4
0.3
43,600
4.5
0.3
53,100
5.5
0.3
81,200
8.5
1.6
93,900
9.8
1.3
112,500
11.7
1.3
12.9
0.9
15.0
1.2
16.9
1.2
20.7
2.3
23.9
3.0
30.7
2.8
3.0 / 100.0
35.9
0.6
6.0 / 100.0
546,700
56.9
0.7
14.0 / 100.0
Water Data
Pressure
Btu/hr
Drop
GPM
(Ft. of
Water)
8,700
1.2
0.4
10,400
1.4
0.6
14,700
2.0
0.2
16,300
2.2
0.2
29,000
4.0
0.4
33,900
4.6
0.6
50,500
6.9
1.8
Maximum
Heat Throw
Min/Max
Mounting
or Spread @
GPM
Height (ft.)
Max. Height

0.3 / 5.0
10
0.3 / 5.0
12
0.4 / 10.0
13
0.4 / 10.0
15
0.5 / 20.0
17
0.5 / 20.0
18
0.8 / 30.0
20
0.8 / 30.0
19
2.0 / 30.0
23
2.5 / 70.0
23
2.5 / 70.0
25
2.5 / 70.0
25
24
158
0.5 / 10.0
14
18
21
0.8 / 15.0
17
23
25
1.0 / 20.0
20
28
31
1.3 / 25.0
20
28
31
1.0 / 30.0
24
33
37
1.3 / 40.0
28
37
41
1.5 / 50.0
29
38
43
38
2.0 / 60.0
29
43
2.0 / 60.0
34
45
51
48
2.3 / 75.0
38
57
2.3 / 75.0
38
48
57
2.3 / 75.0
38
46
57
48
57
72
47
55
70
48
72
Air Data
Maximum
Heat Throw
Mounting
or Spread @
Height (ft.)
Max. Height


10
13
12
14
13
16
15
21
17
21
18
23
20
23
AIR 1-550.30
Air Data
Outlet
Final Air
CFM
Velocity
Temp.
‚
(Fpm)
(°F)

21
364
650
22
435
775
26
695
730
34
855
890
35
1,170
695
38
1,510
890
38
2,150
815
31
2,070
785
48
3,480
920
54
4,655
735
57
5,040
800
57
5,575
760
12,400
2,445
14
960
835
17
1,190
1,035
21
1,740
1,170
21
1,760
1,180
25
2,860
1,380
28
3,400
1,640
29
3,710
1,790
29
3,830
1,845
35
5,110
2,030
39
5,790
2,300
39
6,340
2,300
49
8,140
1,970
49
11,000
2,670
48
12,400
2,445
12,800
2,440
102
Outlet
Final Air
CFM
Velocity
Temp.
‚
(Fpm)
(°F)
230
410
94
265
475
95
430
455
91
540
570
87
725
435
96
925
550
93
1,330
510
94
200°F ENTERING
WATER
60°F ENTERING
AIR
20°F WATER
TEMPERATURE
DROP
Motor Data
Approx.
Hp
RPM
88
1/60
1,550
88
1/25
1,550
85
1/25
1,550
82
1/12
1,550
89
1/12
1,550
87
1/8
1,625
88
1/8
1,625
89
1/5
1,075
89
1/3
1,075
89
1/2
1,075
89
1/2
1,075
93
1/2
1,075
86
1 1/2
1,140
83
1/30
1,050
86
1/30
1,050
84
1/15
1,050
89
1/15
1,050
87
1/6
1,075
86
1/3
1,075
89
1/3
1,075
91
1/3
1,075
87
1/2
1,075
87
1/2
1,075
90
3/4
1,140
87
1
1,140
85
1 1/2
1,140
86
1 1/2
1,140
2
1,140
Motor Data
Approx.
Hp
RPM
1/60
1,000
1/25
1,000
1/25
1,000
1/12
1,000
1/12
1,000
1/8
1,000
1/8
1,000
11