If the procedures listed below do not remedy the problem, the pump will require service and should be taken to an Authorized
SIMPLEX Service Center for repair.
PROBLEM
Sporadic Tool Action
Engine Will Not Start
Noisy Operation
Pump Oil is Over Heating
Pump Runs but Will Not Pump Oil
or build full pressure
SECTION V
TROUBLESHOOTING
CAUSE - SOLUTION
1. Air in the hydraulic system. See Sec. 3-3 for correct
bleeding procedure.
2. Check reservoir oil level.
1. Check manufacturers operating instructions.
1. Air in system. (See Sec. 3-3 for bleeding procedure).
2. Be sure the oil reservoir is filled to normal level.
3. Check all points where air might leak into system.
1. Oil viscosity too high. Replace with SIMPLEX oil.
2. Check for high pressure leakage at relief valve or plugs .
3. Oil level is low. Fill reservoir to normal level or refit pump
with larger reservoir.
1. Pump is not primed. Run pump a few minutes tipping
from side to side.
2. Internal leakage. Take to SIMPLEX Authorized Service
Center for repair.
3. Damaged O-Rings. Take to nearest Simplex Authorized
Service Center.
4. Defective control valve. (Troubleshoot separately).