Quick Start
Version 2017V2
1 Warning
HIKOB housings are not intended to be mounted or disassembled by the user. The complete
assembly is done by HIKOB or by a representative.
2
Commissioning
- Connect the HIKOB gateway to a PoE injector via an Ethernet cable.
- The HIKOB gateway is configured to obtain a dynamic IP address using DHCP.
But there is a specific IP configuration to access the HIKOB GATEWAY:
PC Configuration:
IP Address: 172.16.48.249
Subnet mask 255.255.255.248
The HIKOB GATEWAY can be accessed at: https://172.16.48.251
WARNING : to be able to reach the HIKOB GATEWAY this IP configuration must be
into a point to point connection (no router, no IP switch between the HIKOB
GATEWAY and the PC).
- Sensors and routers are autonomous, no action is required for their commissioning
3 Setting up the sensor network
Once the HIKOB gateway is switched on, the sensors will automatically connect to it. This
step can take up to 1 ½ hours because to save their battery, the sensors periodically scan
the radio space when not yet connected.
The reconnection to the HIKOB network can be accelerated by using a magnet to wake-up
the WISECOW sensors.
4 Web-based management and visualization interface
-
The interface is accessible on the IP network to which the gateway is set, at the following
address: https: // {IP_passerelle_hikob}
-
For the first connection to the HIKOB GATEWAY you must validate the security exception.
-
The login is: "admin" and the password: "HiK0B**". 0 is a zero.
5 REST server
A REST server can be queried at the following address: https: // login: password @
{IP_passage_hikob} / URI