Dea Ghost 100/24CL 사용 지침 및 경고 - 페이지 6

{카테고리_이름} Dea Ghost 100/24CL에 대한 사용 지침 및 경고을 온라인으로 검색하거나 PDF를 다운로드하세요. Dea Ghost 100/24CL 17 페이지. Underground electro-mechanical operator for swing gates

Dea Ghost 100/24CL 사용 지침 및 경고

7 MAINTENANCE

Good preventive maintenance and regular inspection ensure
long working life. In the table below you will find a listo f inspections/
maintenance operations to be programmed and executed periodi-
cally.
Consult the TROUBLE-SHOOTING" table whenever anomalies are
observed in order to find the solution to the problem and contact
DEA System directly whenever the solution required is not provided.
Description
When the opening command is given, the gate wing fails to
move and the operator's electric motor fails to start.
When the opening command is given, the motor starts but
the gate leaf fails to move.
The operator jerks or is noisy during movement, it stops
midway or else it does not start.

8 PRODUCT DISPOSAL

GHOST 100 consists of materials of various types, some of which can be recycled (electrical cables, plastic, aluminum, etc. ..) while
others must be disposed of (electronic boards and components).
Proceed as follows:
1. Disconnect the power supply;
2. Disconnect and disassemble all the accessories connected. Follow the instructions in reverse to that described in the section "Installa-
tion";
3. Remove the electronic components;
4. Sorting and disposing of the materials exactly as per the regulations in the country of sale.
WARNING In line with EU Directive 2012/19/EU for waste electrical and electronic equipment (WEEE), this electrical product must
not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to your local municipal collection
point for recycling.
8
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release mechanism operation
check that water flows out properly from
the foundation box
greasing of articulated joint
TROUBLE-SHOOTING
The operator is not receiving correct power supply. Check all connections, fuses, and the
power supply cable conditions and replace or repair it if necessary. If the gate does not close
check if the photocells work properly.
Make sure the unlocking system is closed.
Make sure that the electronic device for power adjustment is in good condition.
If the leaf of the gate does not move freely, release the operator and readjust the rotation
points.
The power of the gearmotor may be insufficient for the characteristics of the gate's leaf;
check the choice of model whenever required.
Make sure that the electronic device for power adjustment is in good condition.
Possible solutions
PERIODICITY
6 months
6 months
6 months
6 months
1 year