Troubleshooting
Problem
Burner will not light with match
Sudden drop in gas flow or reduced flame height
Irregular flame pattern, flame does not run the
full length of burner
Flame is yellow or orange
Flame goes out
Flashback (fire in venturi/burner tube(s))
Flame seems to lose heat when burning in cold
weather - temperature below 50ºF
Possible Cause
LP gas tank valve is closed
No gas flow
LP gas tank is low or empty
LP gas leak
Coupling nut and regulator not fully connected
Obstruction of gas flow
Disengagement of burner to valve
Spider webs or insect nest in burner/venturi tube
Burner ports clogged or blocked
Out of gas
Excess flow; safety device may have been activated
Burner ports are clogged or blocked
New burner may have residual manufacturing oils
Spider webs or insect nest in burner/venturi tube
Poor alignment of valve to burner/venturi tube
High or gusting winds
Low on LP gas
Excess flow valve tripped
Burner and/or burner/venturi tube is blocked
Ice has built up on the outside of the LP gas tank
because the vaporization process is too slow
For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.
Replacement Parts
parts.BlueRhino.com /
1.800.762.1142
Prevention/Cure
Make sure regulator is securely attached to the LP gas tank per "Installing LP
Gas Tank" section, then turn LP gas tank valve to "OPEN"
Check if LP gas tank is empty
A. If empty exchange, refill or replace
B. If LP gas tank is not empty, refer to "Sudden drop in gas flow or reduced
flame height"
Exchange, refill or replace LP gas tank
1.
Turn LP gas tank valve to "CLOSED"
2.
Wait 5 minutes for gas to clear
3.
Follow "Checking for Leaks" section
Turn the coupling nut about one-half to three-quarter additional turn until solid
stop. Tighten by hand only - do NOT use tools.
1.
Clear burner/venturi tube
2.
Check for bent or kinked hose
Re-engage burner and valve
Clean burner/venturi tube
Clean burner ports
Exchange, refill or replace LP gas tank
1.
Turn control knob to " OFF"
2.
Wait 30 seconds and light outdoor fireplace per "Lighting" section
3.
If flames are still too low, reset the overfilling prevention device:
a. Turn control knob " OFF"
b. Turn LP gas tank valve to "CLOSED"
c. Disconnect regulator
d. Turn control knob to (HIGH)
e. Wait one minute
f.
Turn control knob to " OFF"
g. Reconnect regulator and leak check connections, being careful not to
fully open valve
h. Light outdoor fireplace per "Lighting" section
Clean burner ports
Burn outdoor fireplace for 15 minutes and reinspect
Clean burner/venturi tube
Ensure burner/venturi tube is properly engaged with valve
Do NOT use outdoor fireplace in high winds
Exchange, refill or replace LP gas tank
Refer to "Sudden drop in gas flow or reduced flame height"
Clean burner and/or burner/venturi tube
1.
Turn LP gas tank valve to "CLOSED"
2.
Turn control knob to " OFF"
3.
Replace with a spare LP gas tank
4.
Reconnect LP gas tank per "Installing LP Gas Tank" section
5.
Follow "Checking for Leaks" section
6.
Light outdoor fireplace per "Lighting" section
9