5.5 Operation with pushbutton over L' release phase

Pin 6 (L') is an release phase
to where an external blind pushbutton
can be connected.
WARNING
Please note that the pin for enabling phase L' (pin 6) is always connected to the mains vol-
tage as long as no active movement is being performed via the Casambi control level.
ATTENTION
Only pushbuttons without latching function and no switches may be connected.
The motor can be destroyed if this is not observed.
NOTE
All movements via the „L' path" control are not detected by Casambi. If you use profiles
A,B,C or D, the indication of the horizontal position is no longer correct. Only a travel to one
of the end points (OT/UT) via the control from Casambi „synchronizes" the display with the
real position again.
As soon as a travel command or an automation object is sent, the manual travel is inter-
rupted. If the device is operated in automated mode, the key inputs T1 and T2 (only 10.752)
must be used.