Gree FLEXX60C 설치 매뉴얼 - 페이지 10

{카테고리_이름} Gree FLEXX60C에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gree FLEXX60C 19 페이지. A coils

Gree FLEXX60C 설치 매뉴얼
A-Coil
When installing in an area directly over a finished ceiling (such as an attic), an
emergency drain pan is required directly under the unit. See local and state codes for
requirements. When installing this unit in an area that may become wet, elevate the unit
with a sturdy, non-porous material. In installations that may lead to physical damage (i.e.
a garage) it is advised to install a protective barrier to prevent such damage.
It is necessary to allow a minimum of 40" between the inlet/outlet of the indoor unit
and wall, as shown below.

4.3 Piping Work

4.3.1 Specification of Connection Pipe
Model
FLEXX24C
FLEXX36C
FLEXX48C
FLEXX60C
4.3.2 Piping Preparation
4.3.2.1 Solder Connection
All cut ends are to be round, burr free, and cleaned. Failure to follow this practice
increases the chances for refrigerant leakage.
External diameter (inch)
Gas pipe
Φ3/4
6
Liquid pipe
Φ3/8