● Dehumidifier does not start.
PROBLEM
When using the drain
hose, there is water in
the bucket.
Bucket full indicator
is lit up.
Unit functions
normally but does
not start up.
● Dehumidifier does not dry air as intended.
Bad dehumidifying
performance
Possible causes
● Power is not supplied to
the dehumidifier or the
power plug is not well
inserted.
● Fuse is blown.
● Bucket is not properly
placed.
● Bucket is full of water.
● Bucket has been
removed.
● Humidity is set too high.
● Check whether there is
any obstacle around the
unit.
● Air filter is dusty and
blocked.
● Doors and windows are
left open.
● Room temperature is too
low.
Solu ons
● Check if power is lost. If
yes, wait for the power to
restore.
● If not, check whether the
power circuit or power
socket has been damaged.
● Check whether the power
plug is loosen.
● Check whether the power
cord is damaged.
● Replace the fuse.
● Empty the bucket and
replace it.
● If you want the air drier,
press «—» to lower the
number or press the CO
button for the unit to
dehumidify continuously.
● Make sure there is no
curtain, shutter or furniture
blocking the dehumidifier.
● Clean the filter.
● Make sure all doors and
windows and other openings
to the outside have been
closed.
● Warm temperatures are
good for dehumidification.
Low temperatures will
reduce unit's effect. This
unit should be used in a
place where temperature
is above 5°C.
13