Gree GDN12AY-K4EBA1A 소유자 매뉴얼 - 페이지 19
{카테고리_이름} Gree GDN12AY-K4EBA1A에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gree GDN12AY-K4EBA1A 20 페이지.
Malfunction
No.
Name
Tube
Temperature
2
Sensor
Malfunction
Humidity
3
Sensor
Malfunction
Freon-lacking
4
protection
High-tempe-
rature over
5
oad protect-
ion
Display
Code
Unit's
Condition
Display
Window
F2
Compressor
and fan
motor stop.
This button
is invalid.
L1
F0
The compr-
essor stops;
the fan mo-
tor keeps on
H3
running.
Possible Causes
● Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
● Some element of display board
may have been put upside down
and cause short circuit.
● Temperature sensor on the eva-
porator is damaged(Please refer
to Checking Table for Temperature
Sensor Resistance).
● Display board is damaged.
● Humidity sensor is short-circuited.
● Humidity sensor is damaged.
● Display board is damaged.
● Refrigerant is leaking.
● System is blocked
● Ambient operation condition is
bad.
● The evaporator and condenser
are blocked with filth.
● The system is abnormal.
16