Gree GDN20AX-K4EBA1B 소유자 매뉴얼 - 페이지 17
{카테고리_이름} Gree GDN20AX-K4EBA1B에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gree GDN20AX-K4EBA1B 19 페이지.
Error Codes
● Unit's Malfunction Codes
Malfunction
No.
Name
Ambient
Temperature
1
Sensor
Malfunction
Tube
Temperature
2
Sensor
Malfunction
Humidity
3
Sensor
Malfunction
Display
Code
Unit's
Condition
Display
Window
F1
Compressor
and fan
motor stop.
This button
is invalid.
F2
L1
Possible Causes
● Ambient temperature sensor is
loosen or is poorly connected
with the terminal of display board.
● Some element of display board
may have been put upside down
and cause short circuit.
● Ambient temperature sensor is
damaged(Please refer to Chec-
king Table for Temperature Sen-
sor Resistance).
● Display board is damaged.
● Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
● Some element of display board
may have been put upside down
and cause short circuit.
● Temperature sensor on the eva-
porator is damaged(Please refer
to Checking Table for Temperature
Sensor Resistance).
● Display board is damaged.
● Humidity sensor is short-circuited.
● Humidity sensor is damaged.
● Display board is damaged.
15