Insert the sealing ring (D) into the threaded sleeve (C)
Thread the clamping nut (E) and the threaded sleeve (C) over the AC cable, and its order is
shown in the figure below.
According to polarities, insert the grounding conductor PE (green‐yellow) in the screw
terminal with the earth sign on the socket screw; the neutral conductor N (blue) in the
screw terminal N on the socket element; and phase L (brown or black) into the screw
terminal L on the socket element then tighten the screw to make sure the wires are
securely connected.
After fasten the three wires with the terminal, combine every component together.
8