Venting Requirements
• Vent system must evacuate to the exterior
(through the roof or side wall).
• DO NOT terminate the vent system in an
attic or other enclosed area.
Use rigid metal/aluminum ventonly.
• NEVER use plastic vent or plastic vent cover.
• Always keep the duct clean to ensure
proper airflow.
• Calculate the following figures before installation:
1. Distance from the floor to the ceiling.
2. Distance between the floor and the
countertop/cooking surface.
3. Distance between the range hood
and the countertop/cooking surface
which is recommended at 27" to 30''.
4. Height of hood and duct cover with
the cabinet.
For the most efficient & quiet operation:
• It is recommended that the range hood be
vented vertically through the roof through
6" (15cm) round metal/aluminum vent or
vented horizontally through the wall through
a rectangular vent measuring 3 ¼''x10''.
• The size of the vent should be uniform.
• If venting vertically, do not use more than
three 90° elbows. Do not install two elbows
together.
• Make sure there is a minimum of 24" (61
cm) of straight vent between the elbows if
more than one elbow is used.
• The length of vent system and number of
elbows should be kept to a minimum to
provide efficient performance.
• The vent system must have a damper. If
roof or wall cap has a damper, DO NOT use
damper (if supplied) on top of the range
hood.
• Use duct tape to seal all joints in the vent
system.
• Use caulking to seal exterior wall or roof
opening around the cap.
Height & Clearance
Cabinet
heigh
t
Range
hood
height
Min: 24"
Max: 30"
Ceilin
g
t
heigh
36" standard
counter
height
9
Cabinet
Range hood
Countertop/Cooking
surfac
e