Bristan IRBS1-CP 설치 지침 및 사용자 설명서 - 페이지 15

{카테고리_이름} Bristan IRBS1-CP에 대한 설치 지침 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Bristan IRBS1-CP 20 페이지. Infrared automatic basin spouts

Bristan IRBS1-CP 설치 지침 및 사용자 설명서
Installation - Water Connections
Flexible Connecting Hose
Care must be taken when connecting the flexible connection hose from the power
supply box to the spout to ensure it does not bend sharply and kink or twist.
See below for recommended ways to fit the flexible connecting hose.
Slight
bend

Operation

Using the Automatic Basin Spout
Place the users hands under the spout
within the sensing range. Once the users
hands have been detected water will flow
constantly until the hands are removed.
After 55 ± 5 seconds the water will stop
flowing.
If the user requires more water remove
hands from the sensing range and wait 4
seconds, then place the hands back into
the sensing range and the water will flow
again.
Note: The sensing range for all models is
23-26cm from the sensor.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
90°
angle
Kinks
Twists
Important:
Failure to follow these
guidelines may result in
poor performance and
damage to the flexible
connection hose.
15