combustible materials. Combustible wall coverings
such as paneling or wallboard may not overlap the
black face of the fireplace. The space between the wall
covering and the fireplace should be sealed with a
heat-resistant material such as rock wool insulation or
mortar. If covering the dace with a noncombustible, use
the flush panel kit. Do not place facing material directly
over the louvered openings.
NOTE: An "L" shaped steel lintel must be installed
across the top of the firebox opening where facing
materials such as brick or stone are used on the face of
the firebox. It acts as a support/firestop. It should be
attached to the face of the fireplace with screws and
sealed to the fireplace with a heat-resistant sealer.
20007435
UVSRC Vent-Free Fireboxes

Servicing

Repair and replacement work should only be done by a
qualified service person.
Always shut off the gas supply and make sure the
appliance is cool before beginning any service opera-
tion.
Always check for gas leaks after servicing.
9