Adey CP1-03-04914 설치 및 서비스 - 페이지 5

{카테고리_이름} Adey CP1-03-04914에 대한 설치 및 서비스을 온라인으로 검색하거나 PDF를 다운로드하세요. Adey CP1-03-04914 19 페이지. Digital pressurisation unit

3 KEY FEATURES

3 .11 The APU Midi comprises of the following main components:-
1 . Moulded tank – Main body of the APU, comprising of an integrated water
tank with warning pipe and weir overflow and mounting the brass pump
assembly, manifold and controller .
2 . Pump assembly – One or two brass peripheral pump units powered by
induction motors, with integrated non return valves and venting screw .
Mounted into the moulded tank with vibration isolating rubber mounts .
3 . Outlet manifold – Brass manifold with pressure transducer used to monitor
system pressure and connection to the pump(s) .
4 . Programmable controller – Intuitive, user set controller allowing system set up
and easy alarm connection .
5 . Wall mounting plate – Robust stainless steel wall mounting plate allowing
quick, easy installation and removal if needed .
6 . Moulded cover – Moulded acrylic capped ABS cover retained to the
moulded tanks with Dual Lock
access .
4
3
2
3 .12 Principle of operation: The pressurisation unit consists of a break tank and
one/two peripheral pumps . The break tank is supplied with mains water from
either the left or right through a flexible hose connected to a float valve and
includes an overflow and weir to maintain an AB air gap in the tank . The unit is
connected to the heating/chiller system via another flexible hose which can
exit the unit on either the left or right . The pumps are connected to the tank
via a rubber connector .
A pressure transducer monitors system pressure and if a reduction in system
pressure is detected, the controller runs the pumps until the system is re-
pressurised to the required pre-set level . If the unit only has a single pump
connected it will run continuously until this level is reached, if the unit is a
twin pump model the pumps run in duty standby mode (the controller will
alternate which pump starts first to even the wear on the pumps) . The pumps
are fitted with non-return valves to ensure system pressure is maintained once
pressurised .
fastening system for quick and easy
TM
5
1
- 8 -

4 INSTALLATION

4 .11 Fill valve flow restrictor guidelines: The side entry fill valve must be fitted
with the correct filter and flow restrictor combination (dependant on the
mains water pressure) into the G ½ threaded tail as outlined below:
Coloured insert - To be used for water pressure between 1 and 4 bar
White insert - To be used for water pressure above 4 bar
6
4 .12 Cold mains feed connection: The connection to the cold water mains inlet is
made using the 15 mm compression flexible hose supplied . Ensure the rubber
sealing washer supplied with the hose is installed when the hose is fitted .
Fig. 3
When tightening ensure the fill valve within the tank is not rotated . If the
valve is rotated it may not function correctly with the risk of flooding . The
hose is made water tight with a sealing washer on assembly, nip tight to
4 to 5 Nm for water tight seal . (Do not overtighten) . See Fig . 6 .
Fig. 4
Fig. 5
Fig. 6
- 9 -