Bristan HOU SHC3DIV C 설치 지침 및 사용자 설명서 - 페이지 2

{카테고리_이름} Bristan HOU SHC3DIV C에 대한 설치 지침 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Bristan HOU SHC3DIV C 2 페이지.
Bristan HOU SHC3DIV C에 대해서도 마찬가지입니다: 설치 지침 및 사용자 설명서 (2 페이지)

Bristan HOU SHC3DIV C 설치 지침 및 사용자 설명서
General Cleaning
Bristan products are made from premium materials, with
hand polishing and electroplated finishes.
Your taps or shower should be regularly cleaned with warm
water, a mild pH-neutral liquid soap, and polished with a soft
cloth. Any residues from soap, toiletries etc. should be rinsed
off straight after use.
Household bleaches and cleaners contain harsh chemicals and
may damage the surface finish. Avoid using abrasive cloths,
scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by
the dye found in some cloths, so it is also important to avoid
hanging cloths on spouts.
Wall Outlet Installation
Choose the location for the wall outlet
and create a 25-30mm hole in the wall.
Ensure your shower accessories have
enough reach from that position.
Finish the wall surface.
Servicing Intervals
To reduce the build up of lime scale
and to ensure this shower works
to its maximum performance we
recommend this shower is serviced
every 6-12 months depending on
the hardness of your water.
Maintenance - Cartridge Cleaning
1
2
Remove
handles.
Gently
IMPORTANT
remove the
Isolate the
concealing
water supply
plate from
before
starting!
the wall.
2.5
mm
4
5
Remove any O-rings and soak all
components in de-scaler and wash off
in clean water. Examine all seals and
Reverse the installation steps,
replace if needed. Use WRAS
ensuring the temperature
approved silicon based grease
stop is aligned correctly.
on all seals.
Operation
Off
Left Outlet
On/More Flow
Increased
Temperature
On/More
Flow Bottom
Outlet
With rear access
Fit the wall outlet,
ensuring the
washers are fitted
either side of
the wall.
Go to Step 6 in the
Installation Steps.
Without rear access
Screw the wall outlet into
the 1/2" female connection,
Follow Step 6 in the
using a suitable thread sealant
Installation Steps, fitting a 1/2"
ensuring the rubber seal is fitted
female connection at the hole in
to the back of the wall outlet.
the wall (not supplied).
3
6
1
Decrease
Temperature
2
3
Follow the Temperature
Adjustment Steps if required.
Troubleshooting
Symptom
Right Outlet
Partially closed isolation valve.
On/More
Instantaneous water heater cycles on and off
Flow
as flow rate or pressure is too low.
Head of water is below the
Decreased
minimum distance required.
Temperature
Are the water supply pressures balanced?
No flow or
low flow rate
Off/Less
Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
Flow
boiler temperature changes.
Airlock or partial blockage in the supply
Hot/Cold water supply has failed
Maximum
Water
Maximum Water Temperature
Temperature
too Hot/Cold
Installtion conditions outside
Hot water temperature is less than 10°C
Outlet Water
above the required blend temperature
Temperature
too Hot/Cold
Instantaneous water not igniting because the
water flow rate is too low.
Instantaneous water not igniting because the
water pressure is too low.
Only hot/
Inlet water supplies are reversed.
cold water
from Shower
Unscrew the
Valve
shrouds.
Remove the
This is normal for a short time after using the
cartridges
Water
and piston.
dripping
If water continues to drip,
from shower
possibly due to the cartridge
Shower does
not turn on
24
Mains water supply turned off.
mm
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers. That's why we offer
solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
where our expert team of advisors will be able to offer you any help and advice.
Increase
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Temperature
Bristan Group Ltd.
UK:
Bristan Group, B78 1SG.
EU:
Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.
Cause
If pressures are unbalanced, a pressure reducing valve
should be used for optimum performance.
Do not use other water outlets when using the shower.
Flush through pipework and filters to ensure removal
pipework.
Check the hot and cold feeds. The shower will not
Refer to the Temperature Setting section to set your
needs adjusting.
Flush through pipework and filters to ensure
Filter/pipe blockage
removal of debris and any airlocks.
operating parameters.
Adjust hot water temperature or wait for water to
reheat if a stored water system is used.
Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.
Refer to the specification for system requirements.
Increase water pressure through the system.
Check the water inlet connections are the correct way
around: Hot on the left, Cold on the right when viewed from
the front. Rework pipework as necessary.
Flush through pipework and filters to ensure removal of
Filter/pipe blockage
This is caused by residual water tension, the build up of
shower.
Remove cartridge and clean, refer to 'Maintenance' section
Closed isolation valve.
Customer Service: +44330 026 6273
Web:
www.bristan.com
Email:
A Masco Company
Remedy
Open isolation valve.
Increase water flow rate or
pressure through system.
Refer to the specification for the
minimum distance required.
of debris and any airlocks.
work if either fails.
desired maximum temperature.
Refer to the specification for the
minimum distance required.
Contact your boiler manufacturer.
debris and any airlocks.
water in the shower.
before starting any maintenance.
Open isolation valve.
Turn on mains water supply.