Airflow 90001002 설치 및 운영 지침 매뉴얼 - 페이지 9

{카테고리_이름} Airflow 90001002에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Airflow 90001002 16 페이지. External wall insulation vent kit

m
NOTE
m
CAUTION
m
NOTE

Installation step EXTERNAL WALL:

m
NOTE
© Airflow
we reserve the right to make changes without prior notice
-
Uno hab Ext. Wall Ins. Vent Kit

Installation step INTERNAL WALL:

5 . Shorten wall installation sleeve.
6 . Position wall installation sleeve with EPP front wedge flush to the internal wall in the core drill hole and align
centrally with the empty conduit (Fig. 7).
NOTE: Note the strength of the plaster or wall covering!
m The wall installation sleeve must not be trimmed on the internal side of the wall!
7 . Position wall installation sleeve "inside" and "outside" with provided fixing wedges (Fig. 8).
m The fixing wedges must not deform the wall installation sleeve when inserted!
m A wall installation sleeve condensate drain gradient of 1°-2° outward must be maintained!
Wall installation sleeve
with EPP front wedge
for condensate drain
Empty
conduit
INTERNAL WALL
8 . Fill annular gap "inside" and "outside" with non-pressurised installation foam (Fig. 9/10).
9 . After a sufficient drying time, remove the protruding fixing wedges and excess installation foam.
If necessary, remove EPP material (lower front wedge) and any installation foam residue for cable entry (Fig. 9).
10 . Create diffusion-tight seal on annular gap (Fig. 10).
Installation
foam
m Cut out
long hole
INTERNAL WALL
11 . Place protective cover on the wall installation sleeve.
1. Remove protective cover.
2. Pull seal onto outside of wall installation sleeve (Fig.11) .
3. Shorten soffit channel to the desired length.
Note the installation requirements for the soffit channel! (see chapter 4.0 Installation overview soffit element)
Fixing wedge
Fig. 7
EPP front wedge
for condensate
drain
INTERNAL WALL
Fig. 9
Sealant
Annular
gap
INTERNAL WALL
Fig.11
9
Installation and Operating Instructions
Fig. 8
Fixing
wedge
Fig.10