The wire which is coloured blue must be connected to the terminal which is
marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
4.21 Fuse: The following fuse size should be used with the appropriate pump:
4.22 Internal Wiring
Do not remove terminal box cover. No user serviceable parts
inside terminal box. Any service work involving the removal
of the terminal box cover must only be undertaken by Bristan
or by one of their approved repairers, or similarly qualified
persons in order to avoid a hazard.
There are no user serviceable electrical items within the pump.
4.23 Supply Cord Replacement
If the supply cord is damaged, it must be replaced by Bristan
or by one of their approved repairers, or similarly qualified
persons in order to avoid a hazard.
4.24 Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:-
HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.
Model
All Models
Fuse Size (AMPS)
5
- 12 -