Majestic fireplaces UVC43 주택 소유자 설치 및 운영 매뉴얼 - 페이지 9
{카테고리_이름} Majestic fireplaces UVC43에 대한 주택 소유자 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Majestic fireplaces UVC43 20 페이지. Vermont castings vent-free gas room heaters homeowner's installation and operating manual
2. Attach wire to switch and install switch into recep-
tacle box. Attach cover plate to switch.
3. Connect wiring to gas valve. (Fig. 10)
ON/OFF
Switch
Fig. 10 Remote switch wiring.
FP382
Alternate Switch Location
REMOTE SWITCH WIRING - NVC
11/20/96
Remote switch can be installed on either side of the
access door. Simply mount the switch to the switch
bracket provided. Screw the bracket on either side of
the frame, lining up the screws with the pre-punched
holes. (Fig. 11)
Fig. 11 Installing remote switch bracket.
IF381
NVC -Remote switch bracket
11/20/96
20000135
Majestic Fireplaces
With the electrical and wall switch wiring connected,
gently slide or lift the heater to the desired location.
If nailing flanges are not already installed, attach
flanges with the screws provided.
Valve
Make sure heater is level. Shimming may be required.
Secure heater in place by nailing or screwing through
nailing flanges into framing. NOTE: Be sure to allow
proper space for sheet rock.
FP382
CAUTION: All joints between the finished wall and the
heater surround (top and sides) may be sealed only
with non-combustible material. Only noncombustible
material can be applied as facing to the heater surround
(the black painted face).
When finishing the heater, never obstruct or modify the
air inlet/outlet top or bottom grilles in any manner.
Finish the wall with the material of your choice. Refer to
Page 5, Figure 3 for specific clearances when installing
a combustible mantel or other combustible projection.
Prepunched
Holes
FP381
UVC / UVS Vent-Free Heaters
®
Slide the Heater in Place
Level and Secure the Heater
Finishing
9