7. Place top left log (BE9 or BF11) onto locator notches.
Ensure log is secure.
8. Place top right log (BE10 or BF12) onto locator
notches. Ensure log is secure.
BE9
BE6
Fig. 14 UVC/UVS36 log placement.
BF10
BF8
Fig. 15 UVC/UVS43 log placement.

Ember Material Placement

LG132
Separate the ember material into small pieces and
UVC/UVS43
place onto the burner in front of the front logs. Do NOT
Log placement
pack down, leave in fluffy, loose condition for most re-
9/8/00 djt
alistic ember effects. Do not install more embers on
the burner than come with the unit.
Application of excess loose material may adversely
affect performance of theheater.
Replacement loose embers must be purchased
through authorized Majestic Fireplaces dealers.
WARNING: All previously applied loose
material must be removed prior to reappli-
cation.

Lava Rock

The lava rock provided with this fireplace must be
placed on the firebox bottom on either side of the
burner assembly. Do not place lava rock in combustion
pan.
Under no circumstances should this lava
rock be placed on any part of the burner
assembly.

Flame Adjustment

For fireplaces equipped with HI/LO valves, flame ad-
justment is accomplished by rotating the HI/LO adjust-
ment knob located near the center of the gas control.
(Fig. 16)
20000135
BE10
BF11
LG131
UVC/UVS36 LOGS
9/8/00 djt
Majestic Fireplaces
Turn
counterclockwise
to decrease
flame height
BE8
Fig. 16 Flame adjustment knob for Honeywell Valve.
BE7
It is important to periodically perform a visual check
of the pilot and burner flames. Compare them to the
Figures 17 or 18. If the flame patterns appear abnor-
mal, contact a qualified service provider for service and
LG131
adjustment.
BF12
BF9
Fig. 17 Correct pilot flame pattern.
LG132
UVC36/UVS43
UVC43/UVS43
Fig. 18 Approximate flame heights for each model.
Upon completing the gas line connection, a small
amount of air will be in the lines. When first lighting unit
with pilot light, it will take a few minutes to purge them-
selves of this air. Once the purging is complete, the
pilot and burner will light and operate as indicated in the
instruction manual. Subsequent lightings of the heater
will not require such purging.
When lit for the first time, the appliance will emit a slight
odor for awhile. This is due to paint and lubricants used
in the manufacturing process. After each lighting, vapor
may condense and fog the glass; this moisture disap-
pears within a few minutes of burning.
UVC / UVS Vent-Free Heaters
®

Flame Characteristics

HV102
Honeywell hi/lo knob
4/5/99 djt
IF449
NOVA SIT PILOT
UVC
2/14/97
LG131
UVC/UVS36 LOGS
9/8/00 djt

First Firing

LG134
UVC/UVS43
Log placement flames
9/8/00 djt
Turn clockwise
to increase
flame height
FP449
LG133
LG134
11