CHARGING
When the low battery percentage icon is displayed the device needs to
be charged. Insert the supplied or other compatible micro USB
charging cable into the unit. Connect the other end to a USB DC charger
(such as a smartphone charger) that provides 5V DC at >=1000mA. Fully
charge for at least 2-3 hours. Avoid charging with a USB computer port
that delivers only 500mA.
PARAMETERS
Technical indicators for CO2
Measuring range: 400-5000PPM
Sensor for CO2 : infrared ( NDIR )
Resolution: 1 PPM
PM2.5, PM10, PM1.0 specifications
Measuring range: 0-999ug/m3
Measuring principle: Laser scattering
Resolution: 1ug/m3
Technical indicators for temperature and humidity
Measuring range: -10-50 ° C
Measuring accuracy: ±1 °C
Humidity range: 20%-85% RH
Measuring accuracy: ±4% RH
8