Green Brook Orion Range OD103B 중요 안전 지침
{카테고리_이름} Green Brook Orion Range OD103B에 대한 중요 안전 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Green Brook Orion Range OD103B 2 페이지. Infra-red motion detector - ip65
•
Please read these instructions carefully before installation and keep safe for future
reference.
IMPORTANT
This product should be installed by a competent person and in accordance with the
current IET Wiring Regulations and Building Regulations.
If in doubt,consult a qualified electrician.
•
Always turn off the mains supply before commencing work.
As the detector responds to changes in temperature, avoid the following situations:-
•
Avoid pointing the detector towards objects with highly reflective surfaces, such as
mirrors etc.
•
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, lights etc.
•
Avoid pointing the detector towards objects that may move in the wind, such as
curtains, tall plants etc.
Switch the mains supply OFF first to prevent electric shock.
1.
Remove the rear cover by removing the
screw and pulling off cover, refer to Dia:1.
Dia:1
Note:
Please refer to Data Sheet on the GreenBrook website -
www.greenbrook.co.uk for wiring sensor in parallel.
'Orion Range'
Infra-red Motion Detector - IP65
Model: OD103 & OD103B
Important Safety Instructions
OD103
FIELD OF DETECTION
INSTALLATION
2.
Connect the mains in and load out
cable according to Dia: 2 feeding
cable through the silicon grommet.
Dia:2
OD103B
Poor Sensitivity