Major tech MT 770 사용 설명서 - 페이지 16

{카테고리_이름} Major tech MT 770에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Major tech MT 770 20 페이지. Clamp meter
Major tech MT 770에 대해서도 마찬가지입니다: 사용 설명서 (16 페이지)

Major tech MT 770 사용 설명서

13. DIODE TEST

1. Set the function switch to
position.
2. Press the
Test range. The meter automatically defaults to
Resistance.
3. Insert the red test lead into the "V Ω ºC ºF HZ"
input terminal and the black lead to the "COM"
terminal.
4. Connect the other end of the test leads to the
component under test. Read the display.
Note:• Use the diode test to check diodes,
Transistors, silicon controlled rectifiers
(SCR's) and other semiconductor devices.
• The test sends a current through a
semiconductor junction, then measures
the junction's voltage drop.
• Normal forward voltage drop (forward bias)
for a good silicon diode is between 0.4V to
0.9V. A reading higher than that indicates
a leaky (defective) diode. A zero reading
indicates a shorted diode.
• Reverse the test leads connection (reverse
bias) across the diode. The display shows
"OL" if the diode is good. Any other
readings indicate the diode is shorted or
resistive (defective).
15
MODE
button to select the Diode
Ω
Diode
range