Major tech MT 770 사용 설명서 - 페이지 7

{카테고리_이름} Major tech MT 770에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Major tech MT 770 20 페이지. Clamp meter
Major tech MT 770에 대해서도 마찬가지입니다: 사용 설명서 (16 페이지)

Major tech MT 770 사용 설명서
4. SPECIFICATIONS
AC Current
Range
Measuring Range Resolution
40A
0 ~ 40.00A
400A
0 ~ 400.0A
1000A
0 ~ 1000A
DC Voltage
Range
Measuring Range Resolution
400mV
0 ~ 400.0mV
4V
0 ~ 4.000V
40V
0 ~ 40.00V
400V
0 ~ 400.0V
600V
0 ~ 600V
AC Voltage
Range
Measuring Range Resolution
400mV
0 ~ 400.0mV
4V
0 ~ 4.000V
40V
0 ~ 40.00V
400V
0 ~ 400.0V
600V
0 ~ 600V
Note: No Autoranging on 400mV AC Range
Resistance
Range
Measuring Range Resolution
400Ω
0 ~ 400.0Ω
4kΩ
0 ~ 4.000kΩ
40kΩ
0 ~ 40.00kΩ
400kΩ
0 ~ 400.0kΩ
4MΩ
0 ~ 4.000MΩ
40MΩ
0 ~ 40.00MΩ
Capacitance
Range
Measuring Range Resolution
40nF
0 ~ 40.00nF
400nF
0 ~ 400.0nF
4µF
0 ~ 4.000µF
40µF
0 ~ 40.00µF
100µF
0 ~ 100.0µF
Frequency
Range
Measuring Range Resolution
5Hz
0 ~ 5.000Hz
50Hz
0 ~ 50.00Hz
500Hz
0 ~ 500.0Hz
5kHz
0 ~ 5.000kHz
50kHz
0 ~ 50.00kHz
500kHz
0 ~ 500.0kHz
5MHz
0 ~ 5.000MHz
10MHz
0 ~ 10.00MHz
Duty Cycle
Range
Measuring Range Resolution
0.5% ~ 99.0%
%
Pulse width:
100µs - 100ms
Temperature
Range
Measuring Range Resolution
-20.0ºC ~ 400.0ºC
ºC
400ºC ~ 1000ºC
-4.0ºF ~ 400.0ºF
ºF
400ºF ~ 1832ºF
6
Accuracy (% of Reading)
0.01 A
± (2.5% + 10 digits)
0.1 A
± (2.5% + 5 digits)
1 A
± (3.0% + 5 digits)
Accuracy (% of Reading)
± (0.8% + 3 digits)
0.1 mV
0.001 V
± (1.5% + 3 digits)
0.01 V
0.1 V
± (2.0% + 3 digits)
1 V
Accuracy (% of Reading)
± (0.8% + 10 digits)
0.1 mV
0.001 V
± (1.8% + 5 digits)
0.01 V
0.1 V
± (2.5% + 5 digits)
1 V
Accuracy (% of Reading)
± (1.0% + 4 digits)
0.1 Ω
± (1.5% + 2 digits)
10 Ω
100 Ω
± (2.5% + 3 digits)
1 kΩ
± (3.5% + 5 digits)
10 kΩ
Accuracy (% of Reading)
± (5.0% + 20 digits)
0.01 nF
± (3.0% + 5 digits)
0.01 nF
± (3.5% + 5 digits)
0.001 µF
0.01 µF
± (5.0% + 5 digits)
0.1 µF
Accuracy (% of Reading)
± (1.5% + 5 digits)
0.001 Hz
0.01 Hz
± (1.2% + 2 digits)
0.1 Hz
Sensitivity: 10Vrms min
1 Hz
10Hz
100 Hz
± (1.2% + 10 digits)
1 kHz
10 kHz
Accuracy (% of Reading)
0.1 %
± (1.2% + 2 digits)
Accuracy (% of Reading)
0.1 ºC
± (3.0% + 5ºC)
1 ºC
0.01 ºF
± (3.0% + 7ºF)
1 ºF