Calibration and Measurement
The gauge can calibrate Zero-point of Fe or Non-Fe, or DELETE wrong
calibrated zero-point of Fe or Non-Fe. It is recommended that the zero-point
be calibrated before use.
Zero-point Calibration of Fe or Non-Fe
•
Press and hold the ZERO button to Zero-point the calibration of the Fe or
Non-Fe measuring mode
•
In the Fe mode, Zero-point calibration of Fe.
•
In the Non-Fe mode, Zero-point calibration of Non-Fe (Less than
50UM(µm) is effective).
Delete Fe or Non-Fe Zero-point
1. Press the SELECT button to enter the MENU
2. Press the UP/DOWN button to SELECT CALIBRATION
3. Press the SELECT button to ENTER CALIBRATION
4. Press the UP/DOWN button to delete the ZERO-POINT of Fe or Non-Fe
5. Press the SELECT button for OK
6. Press the BACK button to RETURN
Delete Functions
In MENU system, you can find following function
•
Delete current data: in measurement interface, you can delete the last
data entry by pressing the BACK button.
•
Delete all data: Enter menu-view; you can delete all current data and
statistics
•
Delete Group data: Enter menu-view-group data; you can delete this
group data by pressing the SELECT button
Trouble Shooting
The following list of error messages explains how to identify and eliminate
faults.
Err1 Fe probe fault
Err2 Non-Fe probe fault
Err3 Both probes.
Err4 Fe probe fault
Err5 Non-Fe probe fault