6.1. DC VOLTAGE MEASUREMENTS
CAUTION: Do not measure DC voltages if a motor on the circuit is
being switched ON or OFF. Large voltage surges may occur
that can damage the meter.
1. Set the function switch to the "DC" position.
2. Insert the black test lead banana plug into the
negative COM jack. Insert the red test lead
banana plug into the positive V jack.
3. Touch the black test probe tip to the negative
side of the circuit. Touch the red test probe tip
to the positive side of the circuit.
4. Read the voltage on the display.
6.2. AC VOLTAGE MEASUREMENTS
CAUTION: Do not measure AC voltages if a motor on the circuit is
being switched ON or OFF. Large voltage surges may occur
that can damage the meter.
1. Set the function switch to "AC" position.
2. Insert the black test lead banana plug into the
negative COM jack. Insert red test lead
banana plug into the positive V jack.
3. Touch the black test probe tip to the neutral
side of the circuit. Touch the red test probe tip
to the "hot" side of the circuit.
4.
Read the voltage on the display
8
7