if codespermitanda separate ground
wireis used, i t is recommended thata
qualified electrician determine thatthe
groundpath
is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrbian
if you
are not sure cooktop is properly
grounded.
Do Not have a fuse in the neutral or
grounding circuit.
The down@aft cooktop must be
connected to the proper electrical voltage
and frequency as specified on the
model/serial rating plate. The model/serial
rating plate is located on the bottom of the
cooktop.
[]
A four-wire or three-wire, singb-phase,
240-volt, 60-Hz, AC-only electrical
supply is required on a separate
30-ampere
circuit, fused on both sides
of the line.
[]
A time-delay
fuse or circuit breaker is
recommended.
The fuse size must not
exceed the circuit rating of the
appliance
as specified
on the
model/serial
rating plate.
[]
CONNECT
WITH COPPER WIRE
ONLY.
[]
Connected
directly
to the fused
disconnect
(or circuit breaker
box)
through flexible, armored
or non °
metallic sheathed,
copper cable (with
ground wire).
[]
Flexible armored cable should connect
cooktop directly to the junction
box.
[]
Fuse both sides of the fine.
[]
Locate the junction
box to allow as
much slack as possible
between the
junction
box and cooktop
so that the
downdraft
eooktop can be moved if
servicing
is ever necessary.
[]
A twist=on connector
and 1/2"
(12.7 mm) U.L o or CSA=listed conduit
connector
must be provided at the
junction
box.
The recommended
minimum
copper
wire size is No.-lO gauge.
However,
wire sizes and connections
must conform
to the requirements
of the National
Electrical
Code, ANSI/NFPA
70 -- latest
edition*, or CSA Standards
C22.1-94,
Canadian
Electrical
Code, Part 1 and
22.2
No. 0-M91 - latest edition** and all local
codes and ordinances.
Wire sizes and
connections
must conform with the rating
of the cooktop.
Copiesofthe standardlistedmay be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts02269
** CSA International
8501 East Pleasant Valley Road
CleveRand,Ohio 44131o5575
The wiring diagram is located on the
bottom of the cooktop.
Twist-on connector
and 1/2" (12.7 ram)
U.L o or CSA-listed
conduit connector
are
not provided.
E
Remove shipping materials and tape
from cooktop.
The blower is set to vent straight out
the back of the cooktop.
To vent to the left side, right side or down
through the bottom of the cabinet, add an
elbow to the blower assembly exhaust vent.
It may be easier to connect appliance
cable to junction
box before inserting
cooktop into cutout. See "Electrical
connections,"
Pages 6-8.
[] front edge of downdraft cooktop is at least
lq/2" (38.1 ram) from front edge of
countertop and parallel to countertop.
[] rear edge of cooktop is at least 3/4"
(19.1 ram) from rear wall as recommended.
[] side edge of cooktop is at least 6 inches
(152 cm) from side wall.
m
Connectvent system.See"Venting
requirements,"Pages4=5.Use duct tape to
sea! all joints.Vent must end with a wall or
roof cap outside the building.
This cooktop must be connected to a
grounded, metallb permanent wiring
system or a ground connector
shoumd be
connected to the ground terminam or wire
bad on the cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through
the 1/2" (1£7 mm) U.L.=or CSA-listed conduit
connector. Complete electrical connection
according to local codes and ordinances.
Make the electrical connection:
Excessive
Weight Hazard
Use two or more peopte to move
and install cooktop.
Failure to do so can result in back
or other injury.
Lift entire
cooktop
up from cutout
when positioning
cooktop
in
countertop
opening.
3m
insert downdraft cooktop into cutout.
Check that:
[] cooktop is centered in cutout.
Electrical
Shock Hazard
Turn power supply off before
connecting
wires.
Use !O-gauge solid copper wire.
Electrically
ground cooktop.
Failure to follow these
instructions
can result in death,
fire, or etectricaJ shock.