Electrical Installation
All electrical installation to be carried out by an approved electrician in accordance with Part
"P" U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations
in the country of installation.
iCON Domestic Fans require a 230V 50Hz supply, it is double insulated so therefore does not
require an earth.
For fans mounted in Zones 1 & 2 as defined in section 701 BS7161:2008 Additional
protection must be provided by a Residual current device (RCD) with a rated residual
operating current not exceeding 30mA .
Wiring with no control module fitted.
N
N
RCD
L
L
SWITCHED FUSE
Optional Modules for iCON and iCON eco 230V
Wiring for control modules with external switching
A
N
RCD
L
3 AMP
SWITCHED FUSE
Wiring for control modules with no external switching
B
N
RCD
L
Refer to instructions supplied with (optional) modules for further information.
3 AMP
N
L
LS
3 AMP
SWITCHED FUSE
Page 6 of 8