All commands must start with 'p.xxxx', where xxxx is a user-
defined four-digit password. The default password is 1234.
For security purposes, this should be changed on commissioning.
& Each command and parameter must be separated by
a period (.)
& Commands can be concatenated (linked), and must be
separated by a space ( )
& The maximum message length is limited to 160 characters
& Commands are not case-sensitive
4. Command Overview
Description
(Password)
P
System
password
(Add Phone)
Add a phone
AP
number to the
system
(Delete Phone)
Delete a phone
DP
number from the
system
(Edit Phone)
EP
Edit a phone
(Airtime)
AT
Loads or queries
airtime
(Airtime)
ACK
Loads or queries
airtime
(Query Phone)
QP
Query phone
settings
(Configuration)
Configure Inputs,
CO
Outputs and
system settings
Parameters
Four-digit password
Phone number(s) (up to 19 digits each).
Output to be activated by a Missed Call or
SMS (OU1/OU2)
Input to be monitored (IN1/IN2)
Sub parameters
User Limit UL (1–65536 activations)²
Output text string (user-configured messages 1-20)
Input text string (user-configured messages 1-20)
2. A user limit restricts the number of
times a Missed Call will activate the unit.
Once the user limit is reached, the phone
number will automatically be deleted from
the system
Phone number (up to 19 digits)
OU1
Activates Output 1
DOU1
Deletes Output 1
OU2
Activates Output 2
DOU2
Deletes Output 2
IN1
Activates Input 1
DIN1
Deletes Input 1
IN2
Activates Input 2
DIN2
Deletes Input 2
DIN1S
Deletes Input 1 string
DIN2S
Deletes Input 2 string
DOU1S
Deletes Output 1 string
DOU2S
Deletes Output 2 string
Load airtime (L)
Query airtime (Q)
Sub-parameters
Airtime voucher number
If you add a 'space' and then the text 'ACK'
to the end of any command, you will receive
an SMS back confirming that the command
has been received by the Module. For
example, p.xxxx.DP.0841234567 ACK
Phone number (up to 19 digits)
OU1PU
Sets Output 1 as pulsed
OU1LA
Sets Output 1 as latched
OU1PT
Sets Output 1 pulse time in
milliseconds
OU2PU
Sets Output 2 as pulsed
OU2LA
Sets Output 2 as latched
OU2PT
Sets Output 2 pulse time in
milliseconds
SS
Requests Signal strength
CS
Changes SIM card PIN number
EP
Enables SIM card PIN checking
DP
Disables SIM card PIN checking
SP
Sets SIM PIN in memory only
QF
Queries the Firmware version
QS
Queries the Module settings
NP
New system password
BE
Backs up EEPROM
RE
Restores EEPROM
IO
Input/Output mappings
QB
Queries the battery voltage
CL
Clears the transaction logs
REBOOT
Reboots the Module
SLE
Enables sticky latches
SLD
Disables sticky latches
RSL
Resets sticky latches
STR
Sets the string number and
associated text
ATE
Enables the automatic hourly
airtime query
ATD
Disables the automatic hourly
airtime query
INxR
Makes the selected Input rising
edge active
INxF
Makes the selected Input falling
edge active
INxB
Makes both of the selected Input
edges active
INxBT
Sets the selected Input Blanking
Time