Frigidaire FFC09C3AW1 서비스 데이터 시트
{카테고리_이름} Frigidaire FFC09C3AW1에 대한 서비스 데이터 시트을 온라인으로 검색하거나 PDF를 다운로드하세요. Frigidaire FFC09C3AW1 2 페이지. Frigidaire ffc09c3aw1: supplementary guide
Frigidaire FFC09C3AW1에 대해서도 마찬가지입니다: 공장 부품 카탈로그 (7 페이지)
![Frigidaire FFC09C3AW1 서비스 데이터 시트](/uploads/products/server2/2059343/2059343.png)
ELECTRICAL CIRCUIT
Power
Blk
See Diagram
Yel
Compressor
Cold
Control
EC6
SYSTEM SCHEMATIC
Heat Exchanger
Condenser
Outlet
Charge
Tube
Drier
SP21
IMPORTANT
If any green grounding
wires are removed dur-
ing
servicing,
they
Wh
must be returned to
their original position
and properly secured.
WIRING DIAGRAM
Run
Capacitor
Yel
Compressor
Controller
Wh
C10
Discharge
Charge Tube
IMPORTANT SAFETY NOTICE
The information provided herein
is designed to assist qualified
repair personnel only. Untrained
persons should not attempt to
make repairs due to the possibili-
ty of electrical shock. Disconnect
power cord before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
9.5°F cut in, -9.2°F cut-out @ number 1 setting
PERFORMANCE (Control @ number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
1
⁄
of cycle)
3
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
1
⁄
of cycle), PSIG
3
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
216787900
SERVICE DATA SHEET
COMPACT CHEST
FREEZER
70°F
90°F
5 to 8°F
5 to 8°F
25-35%
40-50%
65-85
70-85
12-0
12-0
110-130
145-165
PD640