WHERE TO PLACE YOUR APPLIANCE

Minimum Clearances To Combustibles

Combustible materials are materials such as wood, paper plant fibres
some plastics. e.g. any material that is capable of being ignited.
Above this appliance:
Minimum of 610mm to combustible materials. NOTE: DO NOT
use this appliance under any awning or pergola if there is a risk of
the structure or materials igniting or being damaged by the heat.
Around this appliance:
Minimum of 1metre to combustible materials.
WHEN CERTAIN MATERIALS OR ITEMS ARE STORED
ABOVE, BESIDE OR UNDER THIS APPLIANCE WHILE IN
USE, THEY WILL BE SUBJECT TO RADIANT HEAT AND
COULD BE SERIOUSLY DAMAGED.
INSTALLATION GUIDELINE
Only use this appliance in an above ground open-air situation with natural ventilation, without stagnant areas, where gas
leakage and products of combustion are rapidly dispersed by wind and natural convection. Any enclosure in which the
appliance is used must comply with one of the following:
1. An enclosure with walls on all sides,
but at least one permanent opening at
ground level and no overhead cover
3. Within a partial enclosure that includes an overhead cover and more than two walls, the following will apply:
(i) at least 25% of the total wall area is completely open, and
(ii) at least 30% of the remaining wall area is open and unrestricted (see Example 4 & 5).
(iii) In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.
1 MTR
2. Within a partial enclosure that
includes an overhead cover and no
more than two walls
610 MM
1 MTR
Page 5