If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are not
sure cooktop is properly grounded.
Do Not have a fuse in the neutral or grounding
circuit.
The downdraft cooktop must be connected to the
proper electrical voltage and frequency as
specified on the model/serial rating plate. The
model/serial rating plate is located on the bottom
of the cooktop.
-
q
Locate the junction box to allow as much slack
as possible between the junction box and
cooktop so that the downdraft cooktop can be
moved if servicing is ever necessary.
q
A U.L.-listed l/2" conduit connector must be
El
A three-wire or four-wire, single-phase,
240+olt, 60-Hz, AC-only electrical supply is
required on a separate 30-ampere circuit, fused
on both sides of the line.
A time-delay fuse or circuit breaker is
recommended. The fuse size must not exceed
the circuit rating of the appliance as specified
on the model/serial rating plate.
CONNECT WITH COPPER WIRE ONLY.
Connected directly to the fused disconnect (or
circuit breaker box) through flexible, armored
or non-metallic sheathed, copper cable (with
ground wire).
Flexible armored cable should connect
cooktop directly to the junction box.
provided at the junction box.
0
0
The recommended minimum copper wire size is
No.-10 gauge. However, wire sizes and
connections must conform to the requirements of
the National Electrical Code, ANSI/NFPA 70 -
latest edition*, and all local codes and ordinances.
Wire sizes and connections must conform with the
rating of the cooktop.
Copies
of the standard
listed may be obtained
from:
l
National Fire Protection Association
Batterymarch
Park
Quincy, Massachusetts
02269
The wiring diagram is located on the bottom of
the cooktop.
q
Fuse both sides of the line.
Q
Remove shipping
1
materials.
/
q
I Preparation
1
n
Remove shipping materials and tape
from cooktop.
2
n
The blower is set to vent straight out
the back of the cooktop.
To vent to the left side, right side or down
through the bottom of the cabinet, add an
elbow to the blower assembly exhaust duct.
ti
: Installation
El
Duct connection
may be easier to connect appliance cable to
unction box before inserting cooktop into
Itout. See D, "Electrical connection,"
Page 5
4
n
Connect duct system. See "Venting
requirements,"
Pages 2-3. Use duct tape to
seal all joints. Duct must end with a wall or
roof cap outside the building.
Excessive Weight Hazard
Use two or more people to move and
install downdraft cooktop.
Failure to follow this instruction
can result
in back or other injury.
ift entire cooktop up from cutout when
ositioning cooktop in countertop opening.
3
n
Insert downdraft cooktop into cutout.
heck that:
3 cooktop is centered in cutout.
3 front edge of downdraft cooktop is at least
l-1/2' from front edge of countertop and
parallel to countertop.
3 rear edge of cooktop is at least 3/4" from rE
wall as recommended.
3 side edge of cooktop is at least 6 inches
from side wall.
Page 4